In buildings, fire safety is not just
a regulatory requirement; it is a crucial measure for saving lives. One of the
most important elements of passive fire protection systems is the fire door
assembly. These assemblies help contain fire and smoke, enabling safe
evacuation and reducing damage.
To ensure performance and reliability,
the Bureau of Indian Standards (BIS) has established specifications through the
Indian Standard IS 3614. This standard requires manufacturers to obtain ISI
certification for fire doors and assemblies, ensuring their products meet
national safety and quality standards.
Let's explore everything you need to know about ISI mark certification for fire doors and assemblies, the Indian Standard for these products, and the steps you can take to achieve compliance.
Importance of ISI Certification for Fire Doors and Assemblies
The ISI mark certification for fire doors and assemblies is essential as it guarantees that these products have been tested for fire resistance and adhere to stringent performance standards. Certification under IS 3614 is increasingly required for government procurement, smart city infrastructure, green building compliance, and projects governed by fire safety regulations. This certification not only ensures reliable performance during fire emergencies but also confirms compliance with national building codes and enhances market credibility.
Key Requirements of Indian
Standard IS 3614
Indian Standard IS
3614, titled “Fire Check Doors — Specification,” outlines the requirements for
the construction, performance, and testing of fire door assemblies used in
various types of buildings. The standard is divided into two parts:
Part 1:
General requirements for construction and performance
Part 2:
Testing for fire resistance and criteria for integrity and insulation
- Construction
Guidelines: Fire doors must be constructed
using fire-rated materials. The design should ensure that door frames are
securely sealed, resist warping and deformation under heat, and maintain
structural integrity for a specified duration (typically 30, 60, 90, or
120 minutes).
- Fire Testing
Parameters: According to IS 3614 Part 2, fire
resistance tests evaluate two main aspects: Integrity, which requires that
the door must not allow flames or hot gases to pass through, and
Insulation, which limits heat transfer to the non-fire side. The doors are
tested in a vertical furnace to replicate real fire conditions.
- Marking and
Identification: Products that conform to IS
3614 must display clear markings, including the manufacturer's details,
fire rating (in minutes), year of manufacture, and the ISI mark (after
approval from the Bureau of Indian Standards, BIS).
This standard is crucial for manufacturers supplying fire doors to residential buildings, commercial complexes, industrial plants, hospitals, hotels, high-rise structures, and public infrastructure.
BIS Certification Process
for Fire Doors and Assembly
To obtain the ISI mark certification
for Fire Doors and Assembly, manufacturers must undergo a thorough process
under the ISI certification scheme:
- Application
Submission: Submit the completed application
form with necessary documentation to BIS.
- Document Review: BIS evaluates the submitted documents to verify accuracy and
completeness.
- Factory Inspection: BIS officials conduct on-site inspections to assess
manufacturing processes and quality control systems.
- Sample Testing: Product samples are collected and tested at BIS-approved
laboratories to verify compliance with Indian standards.
- Certification Grant: Upon successful inspection and testing, the BIS issues the certification, allowing the use of the ISI Mark.
Documents Required for BIS Certification
To apply for ISI
Certification for Fire Doors and Assembly, manufacturers must provide the
following documents:
● Completed application form
● Detailed manufacturing process
information
● Quality control plans and test
reports
● Factory layout and equipment
details
● Product specifications and
technical details
● Business registration proof
● Declaration of conformity to
Indian standards
Additional documentation may be required based on product specifications and environmental regulations.
BIS ISI Mark Certification Costing And Timeline
To Know The Process in Detail, Please Visit:
Under BIS Registration Products ISI and CRS
Conclusion
In a country experiencing rapid urban growth and infrastructure expansion, the demand for certified fire safety systems has become increasingly critical. By adhering to the Indian Standard IS 3614, manufacturers of fire doors and assemblies not only comply with legal requirements but also play a vital role in creating safer environments.
Suppose you are a manufacturer or
stakeholder in the fire safety or construction industry. In that case,
obtaining ISI certification for Fire Doors and Assemblies is an essential step
in positioning your product as reliable, tested, and compliant. If you need
assistance with the BIS certification process for IS 3614, the EVTL India team
can guide you through every step, from the application process to lab testing
and final approval. Contact us today to get started.